Low Voltage Cables
Unity Cables is a leading supplier of low voltage electrical cables.
Cabtyre
Flexible wiring cable
Low Voltage Cable Description
High conduct bunched plain flexible copper conductors to SANS 1411 Part1. Insulated and colour coded with general purpose flexible grade PVC to SANS 1411 Part 2. Cores are twisted together and sheathed with a flexible grade PVC.
Instillation Information:
For supplying power to all types of electrical, domestic and industrial appliance and equipment such as:
- Electrical Lawnmowers
- Power Tools
- Kitchen Appliances
- Extension Leads
- Multiplug Extentions
- Small Industrial Machinery
Click Here For Technical Information
TECHNICAL INFORMATION | ||||||||||||||
CABLE SIZE | CONDUCTOR STRANDS No. x DIAMETER | APPROX. OVERALL DIAMETER | CURRENT RATING NOTE 1 | VOLT DROP NOTE 1 | APPROX. CABLE WEIGHT MASS PER 100M COIL | |||||||||
(mm²) | (mm) | (A) | (MV/A/M) | (kg) | ||||||||||
2C | 3C | 4C | 5C | 7C | 2C | 3, 4, 5, & 7C | 2C | 3C | 4C | 5C | 7C | |||
LIGHT DUTY | ||||||||||||||
0.5 | 16 x 0.20 | 5.2 | 5.6 | 6.1 | 6.6 | 3 | 93 | 80 | 3.5 | 4.2 | 5.1 | 6.7 | - | |
0.75 | 24 x 0.20 | 5.7 | 5.9 | 6.6 | - | - | 6 | 62 | 54 | 4.9 | 5.6 | 6.70 | - | - |
HEAVY DUTY | ||||||||||||||
0.75 | 24 x 0.20 | 6.1 | 6.5 | 7.0 | 7.9 | 9.3 | 6 | 62 | 54 | 5.8 | 6.8 | 8.0 | 9.9 | 12.2 |
1.0 | 30 x 0.20 | 6.7 | 7.11 | 7.76 | 8.6 | 10.9 | 10 | 46 | 40 | 6.7 | 7.6 | 9.7 | 11.6 | 14.8 |
1.5 | 30 x 0.25 | 7.8 | 8.50 | 9.50 | 10.1 | 13.2 | 16 | 32 | 27 | 8.9 | 10.6 | 13.4 | 16.2 | 20.6 |
2.5 | 50 x 0.25 | 9.5 | 10.4 | 11.3 | 12.2 | 14.1 | 20 | 19 | 16 | 13.4 | 16.0 | 20.1 | 24.2 | 31.5 |
4.0 | 56 x 0.30 | 10.3 | 11.7 | 12.9 | 14.1 | 25 | 12 | 10 | 17.6 | 22.2 | 27.5 | 33.9 | - | |
Note 1: Based on max ambient temperature of 30°C and max conductor temperature of 70°C |
Low Voltage Cables
Unity Cables is a leading supplier of low voltage electrical cables.
Cabtyre
Flexible wiring cable
Low Voltage Cable Description
High conduct bunched plain flexible copper conductors to SANS 1411 Part1. Insulated and colour coded with general purpose flexible grade PVC to SANS 1411 Part 2. Cores are twisted together and sheathed with a flexible grade PVC.
Instillation Information:
For supplying power to all types of electrical, domestic and industrial appliance and equipment such as:
- Electrical Lawnmowers
- Power Tools
- Kitchen Appliances
- Extension Leads
- Multiplug Extentions
- Small Industrial Machinery
Flat Twin and Earth
Innocative wiring cable
Low Voltage Cable Description
Copper Conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2, laid up with a bare copper earth-continuity-conductor between them, PVC sheathed to SANS 1411 Part 2.
Instillation Information:
- Surface Wiring
- Under-plaster wire
- Wiring Of Hollow Walls
- Roof Access Wiring
Click Here For Technical Information
TECHNICAL INFORMATION | ||||||
CABLE SIZE | CONDUCTOR TYPE | APPROX. OVERALL DIAMETER | CURRENT RATING NOTE 1 | VOLT DROP NOTE 1 | APPROX. CABLE WEIGHT MASS PER 100M COIL | |
(mm²) | (Main) | (Earth) | (mm) | (A) | (MV/A/M) | (kg) |
1 | 1/1.5 | 1/1.5 | 7.9 x 4.3 | 15 | 44.0 | 6.76 |
1.5 | 1/1.38 | 1/1.15 | 8.8 x 4.8 | 19 | 29.0 | 8.33 |
2.5 | 1/1.78 | 1/1.38 | 10.4 x 5.6 | 27 | 18.0 | 11.7 |
4 | 7/0.86 | 1/1.38 | 12.2 x 6.2 | 36 | 11.0 | 18.3 |
6 | 7/1.04 | 1/1.78 | 13.7 x 7.2 | 46 | 7.3 | 23.4 |
10 | 7/1.38 | 7/0.86 | 17.2 x 8.6 | 63 | 4.4 | 37.1 |
16 | 7/1.72 | 7/1.04 | 20.0 x 9.8 | 85 | 2.8 | 52 |
Note 1: These ratings are for 2 cables single phase AC or DC clipped direct as per SANS 0142 table 6.3 #Conductors of 4mm² and over are stranded |
Flat Twin and Earth
Innocative wiring cable
Low Voltage Cable Description
Copper Conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2, laid up with a bare copper earth-continuity-conductor between them, PVC sheathed to SANS 1411 Part 2.
Instillation Information:
- Surface Wiring
- Under-plaster wire
- Wiring Of Hollow Walls
- Roof Access Wiring
Surfix
Innovative wiring cable
Low Voltage Cable Description
Copper Conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2, laid up with a bare tinned copper earth wire in contact with a longitude aluminum/ polyethylene/ laminate, UV stable PVC sheathed to SANS 1411 Part 2.
Instillation Information:
- Surface wiring
- Under-plastering wiring
- Wiring in hollow walls
- Wiring in roof spaces
Click Here For Technical Information
TECHNICAL INFORMATION | ||||||||||||
CABLE SIZE | CONDUCTOR TYPE | APPROX. OVERALL DIAMETER | CURRENT RATING NOTE 1 | VOLT DROP NOTE 1 | APPROX. CABLE WEIGHT MASS PER 100M COIL | |||||||
(mm²) | (mm) | (A) | (MV/A/M) | (kg) | ||||||||
MAIN | EARTH | 2C | 3C | 4C | 2C | 3C & 4C | 2C | 3 & 4 | 2C | 3C | 4C | |
1.5 | 1.5 | 1/1.15 | 8.1 | 7.6 | 8.8 | 19 | 17 | 29.0 | 25.0 | 10.2 | 12.1 | 14.1 |
2.5 | 2.5 | 1/1.38 | 9.4 | 8.8 | 10.3 | 27 | 24 | 18.0 | 15.0 | 14.4 | 16.5 | 19.6 |
4.0 | 4.0 | 1/1.38 | 11.1 | 10.4 | 12.2 | 36 | 32 | 11.0 | 9.5 | 18.6 | 23.5 | 28.1 |
6.0 | 6.0 | 1/1.78 | 12.3 | 11.5 | 13.5 | 46 | 41 | 7.3 | 6.4 | 27.5 | 31.7 | 41.4 |
10.0 | 10.0 | 7/0.86 | 14.4 | 63 | 4.4 | 35.6 | ||||||
Note 1: These ratings are for 2 cables single phase AC or DC clipped direct as per SANS 0142 table 6.3 |
Surfix
Innovative wiring cable
Low Voltage Cable Description
Copper Conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2, laid up with a bare tinned copper earth wire in contact with a longitude aluminum/ polyethylene/ laminate, UV stable PVC sheathed to SANS 1411 Part 2.
Instillation Information:
- Surface wiring
- Under-plastering wiring
- Wiring in hollow walls
- Wiring in roof spaces
Submersible Pump
3 and 4 core cable
Low Voltage Cable Description
High conductivity bunch plain flexible copper conductors to SANS 1411 Part1. Core insulated and bedded with Flexible PVC Grade. Final protection is given by a flexible PVC outer sheath
Instillation Information:
- Quarries
- Farms
- Cleaning & Sewerage extraction plants
- De-watering
- Boreholes
Click Here For Technical Information
TECHNICAL INFORMATION | |||||
CABLE SIZE | NOMINAL STRANDING No. x DIAMETER | APPROX. OVERALL DIAMETER | CURRENT RATING NOTE 1 | VOLT DROP NOTE 1 | APPROX. CABLE WEIGHT MASS PER 100M COIL |
(mm²) | (mm) | (A) | (MV/A/M) | (kg) | |
1.5 x 3 | 28w x 0.25 | 9.0 | 15 | 26.00 | 12.0 |
2.5 x 3 | 46w x 0.25 | 10.0 | 20 | 16.00 | 17.0 |
4.0 x 3 | 52w x 0.30 | 11.9 | 30 | 10.00 | 23.0 |
6.0 x 3 | 84w x 0.30 | 14.5 | 35 | 6.40 | 42.0 |
10.0 x 3 | 140w x 0.30 | 17.0 | 50 | 3.80 | 52.0 |
16.0 x 3 | 210w x 0.30 | 19.0 | 65 | 2.40 | 7u0 |
4 Core (mm²) | (mm) | (A) | (MV/A/M) | (kg) | |
1.5 x 4 | 28w x 0.25 | 10.5 | 15 | 26.00 | 20.0 |
2.5 x 4 | 46w x 0.25 | 11.0 | 20 | 16.00 | 25.0 |
4.0 x 4 | 52w x 0.30 | 13.5 | 30 | 10.00 | 32.0 |
6.0 x 4 | 84w x 0.30 | 16.0 | 35 | 6.40 | 48.0 |
10.0 x 4 | 140w x 0.30 | 18.3 | 50 | 3.80 | 68.0 |
16.0 x 4 | 210w x 0.30 | 21.0 | 65 | 2.40 | 90.0 |
Note 1: Based on max ambient temperature of 30°C and conductor temperature of 70°C |
Submersible Pump
3 and 4 core cable
Low Voltage Cable Description
High conductivity bunch plain flexible copper conductors to SANS 1411 Part1. Core insulated and bedded with Flexible PVC Grade. Final protection is given by a flexible PVC outer sheath
Instillation Information:
- Quarries
- Farms
- Cleaning & Sewerage extraction plants
- De-watering
- Boreholes
Nitrile Trailing
Flexible PVC – 4 Core Cable
Low Voltage Cable Description
High conductivity bunch plain flexible copper conductors to SANS 1411 Part1. Core insulated and bedded with Flexible PVC . Flexible Grade PVC/ Nitrile outer sheath
Instillation Information:
- Power supply of mobile and stationary industrial machinery
- Applications that require medium duty abrasion and where oil and water resistance is required
Click Here For Technical Information
TECHNICAL INFORMATION | |||||
CABLE SIZE | NOMINAL STRANDING No. x DIAMETER | APPROX. OVERALL DIAMETER | CURRENT RATING NOTE 1 | VOLT DROP NOTE 1 | APPROX. CABLE WEIGHT MASS PER 100M COIL |
(mm²) | (mm) | (A) | (MV/A/M) | (kg) | |
1.5 x 4 | 30w x 0.25 | 12.0 | 16 | 27.00 | 22.0 |
2.5 x 4 | 50w x 0.25 | 13.5 | 25 | 16.00 | 27.0 |
4.0 x 4 | 56w x 0.30 | 15.5 | 32 | 10.00 | 38.0 |
6.0 x 4 | 84w x 0.30 | 18.0 | 37 | 6.50 | 52.0 |
10.0 x 4 | 140w x 0.30 | 20.0 | 50 | 3.80 | 72.0 |
16.0 x 4 | 224w x 0.30 | 24.0 | 65 | 2.40 | 104.0 |
25.0 x 4 | 376w x 0.30 | 28.0 | 89 | 1.50 | 149.0 |
Note 1: Based on max ambient temperature of 30°C and conductor temperature of 70°C |
Nitrile Trailing
Flexible PVC – 4 Core Cable
Low Voltage Cable Description
High conductivity bunch plain flexible copper conductors to SANS 1411 Part1. Core insulated and bedded with Flexible PVC . Flexible Grade PVC/ Nitrile outer sheath
Instillation Information:
- Power supply of mobile and stationary industrial machinery
- Applications that require medium duty abrasion and where oil and water resistance is required
PVDAC
Low-voltage PVC Cable
Low Voltage Cable Description
Electrical and physical properties of 3 and 4 core PVC insulated PVC bedded *SWA PVC sheathed 600/1000 V cables with aluminium or copper conductors and manufacturers to SANS 1507-3.
*Where the armouring of cables is used as the earth continuity path, it may be necessary to replace some of the steel wires with tinned copper wires (ECC) or to use a supplementary earth.
Click Here For Technical Information
TECHNICAL INFORMATION | |||||||||||
CABLE SIZE | APPROX. OVERALL DIAMETER | CURRENT RATING NOTE 1 | VOLT DROP NOTE 1 | APPROX. CABLE WEIGHT MASS PER 100M COIL | |||||||
(mm²) | (mm) | (A) | (MV/A/M) | (kg) | |||||||
2C | 3C | 4C | 7C | 2C | 3, 4, & 7C | 2C | 3C | 4C | 7C | ||
1.5 | 13.9 | 14.4 | 17.2 | 17.2 | 21 | 18 | 29 | 38 | 44 | 48 | 61 |
2.5 | 14.6 | 15.2 | 18.3 | 18.3 | 28 | 25 | 18 | 44 | 9 | 56 | 74 |
4 | 16.7 | 17.4 | 21.2 | 21.2 | 38 | 33 | 11 | 56 | 64 | 73 | 99 |
6 | 17.8 | 18.8 | 23.2 | 23.2 | 49 | 42 | 7.3 | 67 | 77 | 88 | 119 |
10 | 19.9 | 20.8 | - | - | 67 | 58 | 4.4 | 84 | 96 | 113 | - |
16 | 17.8 | 20.1 | - | - | 89 | 77 | 2.8 | 76 | 103 | 128 | - |
25 | - | 26.5 | - | - | 118 | 102 | 1.75 | - | 164 | 192 | - |
35 | - | 27.9 | - | - | 145 | 125 | 1.25 | - | 220 | 237 | - |
50 | - | 31.5 | - | - | 175 | 151 | 0.93 | - | 287 | 320 | - |
70 | - | 35.5 | - | - | 222 | 192 | 0.63 | - | 361 | 450 | - |
95 | - | 40 | - | - | 269 | 231 | 0.46 | - | 490 | 596 | - |
120 | - | 42.2 | - | - | 310 | 67 | 0.36 | - | 572 | 710 | - |
150 | - | 46 | - | - | 356 | 306 | 0.29 | - | 690 | 925 | - |
185 | - | 51.2 | - | - | 405 | 348 | 0.23 | - | 869 | 1103 | - |
240 | - | 57.2 | - | - | 476 | 409 | 0.18 | - | 1076 | 1372 | - |
300 | - | 62.2 | - | - | 547 | 469 | 0.145 | - | 1295 | 1654 | - |
Note 1: These ratings are per SANS 0142 table 6.4 |
PVDAC
Low-voltage PVC Cable
Low Voltage Cable Description
Electrical and physical properties of 3 and 4 core PVC insulated PVC bedded *SWA PVC sheathed 600/1000 V cables with aluminium or copper conductors and manufacturers to SANS 1507-3.
*Where the armouring of cables is used as the earth continuity path, it may be necessary to replace some of the steel wires with tinned copper wires (ECC) or to use a supplementary earth.
Single Core
Low-Voltage PVC Cable
Low Voltage Cable Description
Electrical and physical properties of single core PVC insulated cables with stranded copper conductors, unarmored or armored, PVC sheathed 600/ 1000V to SANS 1507-3
Click Here For Technical Information
TECHNICAL INFORMATION | |||||
CABLE SIZE | NOMINAL STRANDING No. x DIAMETER | APPROX. OVERALL DIAMETER | CURRENT RATING NOTE 1 | VOLT DROP NOTE 1 | APPROX. CABLE WEIGHT MASS PER 100M COIL |
(mm²) | (mm) | (A) | (MV/A/M) | (kg) | |
1.0 | 7 x 0.43 | 2.9 | 15 | 44.00 | 1.7 |
1.5 | 7 x 0.53 | 3.2 | 20 | 29.00 | 2.3 |
2.5 | 7 x 0.66 | 3.6 | 27 | 18.00 | 3.3 |
4.0 | 7 x 0.85 | 4.5 | 37 | 11.00 | 5.2 |
6.0 | 7 x 1.04 | 5.1 | 47 | 7.30 | 7.2 |
10.0 | 7 x 1.35 | 6.0 | 65 | 4.40 | 11.2 |
16.0 | 7 x 1.67 | 7.0 | 87 | 2.80 | 17.0 |
25.0 | 19 x 1.31 | 8.6 | 114 | 1.75 | 26.6 |
35.0 | 19 x 1.53 | 10.0 | 141 | 1.25 | 35.7 |
50.0 | 19 x 1.78 | 11.5 | 182 | 0.95 | 48.3 |
70.0 | 19 x 2.14 | 13.3 | 234 | 0.66 | 68.0 |
95.0 | 19 x 2.52 | 15.5 | 284 | 0.50 | 94.0 |
120.0 | 37 x 2.03 | 17.1 | 330 | 0.41 | 115.4 |
150.0 | 37 x 2.25 | 19.0 | 381 | 0.34 | 122.6 |
185.0 | 37 x 2.52 | 21.2 | 436 | 0.29 | 179.0 |
240.0 | 61 x 2.25 | 24.1 | 515 | 0.25 | 232.5 |
300.0 | 61 x 2.52 | 27.0 | 594 | 0.22 | 195.0 |
400.0 | 61 x 2.80 | 30.3 | 694 | 0.20 | 375.0 |
500.0 | 61 x 3.20 | 34.1 | 792 | 0.185 | 479.0 |
630.0 | 91 x 2.97 | 38.0 | 904 | 0.175 | 612.0 |
Note 1: These ratings are for single cables single phase AC or DC clipped direct as per SANS 0142 table 6.2 |
Single Core
Low-Voltage PVC Cable
Low Voltage Cable Description
Electrical and physical properties of single core PVC insulated cables with stranded copper conductors, unarmored or armored, PVC sheathed 600/ 1000V to SANS 1507-3
Multicore
Low-Voltage PVC Cable
Low Voltage Cable Description
Electrical and physical properties of Multicore PVC insulated PVC bedded *SWA PVC sheathed 600/100V cables with stranded copper conductors manufactured to SANS 1507-3.
*Where the armouring of cables is used as the earth continuity path, it may be necessary to replace some of the steel wires with tinned copper wires (ECC) or to use a supplementary earth
Multicore
Low-Voltage PVC Cable
Low Voltage Cable Description
Electrical and physical properties of Multicore PVC insulated PVC bedded *SWA PVC sheathed 600/100V cables with stranded copper conductors manufactured to SANS 1507-3.
*Where the armouring of cables is used as the earth continuity path, it may be necessary to replace some of the steel wires with tinned copper wires (ECC) or to use a supplementary earth
AIRDAC SNE
House Service Connecting Cable (with or without pilot cords)
Low Voltage Cable Description
Circular stranded hard drawn copper phase conductor, XPLE insulated with concentrically arranged identified neutral and bare earth conductors. Polyethlene sheathed 600/1000V service connection cable. Nylon ripcord laid under sheath. Manufactured to to SANS 1507 and NRS 063.
- Small overall diameter – concentric construction (SNE – Separate Neutral Earth
- Lower Mass – due to smaller diameter – no steel wire armor
- Increased safety – reliable earthing
- Improved Reliability – UV stable sheath and core insulation and water blocked
- Tamper and vandal proof – unauthorized access to phase conductor inhibited by concentric layer.
- Easy strip with nylon ripcord
Click Here For Technical Information
TECHNICAL INFORMATION | ||
CABLE SIZE (mm²) | 10 | 16 |
Phase Conductor Resistance (0hm/Km) DC @ 20 ° C | 1.89 | 1.19 |
Phase Conductor Impedance (0hm/Km) | 2.34 | 1.47 |
Phase Conductor Strand Size (mm) & No. | 1.35 x 7 | 1.74 x 7 |
Phase Conductor Insulation Thickness (mm) | 0.7 | 0.7 |
Phase Conductor OD (mm) | 5.45 | 6.41 |
Neutral Size (mm²) | 10 | 16 |
Neutral Conductor Strand Size (mm) & No. | 1.33 x 7 | 1.67 x 7 |
Earth Size (mm²) | 7.5 | 11 |
Earth Conductor Strand Size (mm) & No. | 1.78 x 3 | 2.2 x 3 |
Communication Cores - Solid - OD (mm) & No. | 0.8 x 2 | 0.8 x 2 |
Current Rating (A) | 67 | 89 |
(In Air 30°C ambient - max Conductor Temperature 90°C) | ||
Nominal Sheath Thickness (mm) | 1.4 | 1.6 |
Approximate Cable OD (mm) | 12 | 14 |
Approximate Cable Mass (Kg/Km) | 319 | 488 |
AIRDAC SNE
House Service Connecting Cable (with or without pilot cords)
Low Voltage Cable Description
Circular stranded hard drawn copper phase conductor, XPLE insulated with concentrically arranged identified neutral and bare earth conductors. Polyethlene sheathed 600/1000V service connection cable. Nylon ripcord laid under sheath. Manufactured to to SANS 1507 and NRS 063.
- Small overall diameter – concentric construction (SNE – Separate Neutral Earth
- Lower Mass – due to smaller diameter – no steel wire armor
- Increased safety – reliable earthing
- Improved Reliability – UV stable sheath and core insulation and water blocked
- Tamper and vandal proof – unauthorized access to phase conductor inhibited by concentric layer.
- Easy strip with nylon ripcord
Aerial Bundle Conductor
Low-Voltage PVC Cable
Low Voltage Cable Description
Self Supporting system consists of four cores of drawn stranded and compacted aluminium conductors of equal cross-section and insulated with carbon-loaded XPLE to ensure to ensure UV protection. All cores strained equally.
Supporting-core system consists of three phase cores of hard-drawn stranded compacted aluminium conductors insulated with carbon-loaded XPLE laid up around an aluminium- alloy supporting core insulated with carbon loaded XPLE to ensure UV protection.
Additional sub-conductors optional in both self-supporting and supporting-core systems.
Click Here For Technical Information
TECHNICAL INFORMATION (SEFL-SUPPORTING SYSTEM) | ||||||||||
DESCRIPTION | NOMINAL CONDUCTOR DIAMETER | NOMINAL CORE DIAMETER | CONDUCTOR RESISTANCE @20°C | CONDUCTOR RESISTANCE @80°C | CURRENT RATING | SHORT CIRCUIT RATING | NOMINAL BUNDLE DIAMETER | MAXIMUM DESIGN LOAD | APPROX. BUNDLE WEIGHT | STANDARD PACKAGING |
(mm) | (mm) | (Ω/km) | (Ω/km) | (A) | (kA) | (mm) | (kN) | (kg/km) | (M) | |
35 x 4 | 7.2 | 10.4 | 0.868 | 1.078 | 144 | 3.2 | 25.1 | 7 | 566.38 | 500/1000 |
50 x 4 | 8.37 | 11.57 | 0.641 | 0.796 | 183 | 4.6 | 27.9 | 9 | 733.08 | 500/1000 |
70 x 4 | 9.95 | 13.55 | 0.443 | 0.550 | 228 | 6.4 | 32.7 | 14 | 979.99 | 500/1000 |
TECHNICAL INFORMATION (SUPPORTING CORE SYSTEM) | ||||||||||
DESCRIPTION | NOMINAL CONDUCTOR DIAMETER | NOMINAL CORE DIAMETER | CONDUCTOR RESISTANCE @20°C | CONDUCTOR RESISTANCE @80°C | CURRENT RATING | SHORT CIRCUIT RATING | NOMINAL BUNDLE DIAMETER | MAXIMUM DESIGN LOAD | APPROX. BUNDLE WEIGHT | STANDARD PACKAGING |
(mm) | (mm) | (Ω/km) | (Ω/km) | (A) | (kA) | (mm) | (kN) | (kg/km) | (M) | |
7.2 | 10.4 | 0.868 | 1.078 | 144 | 3.2 | 25.1 | 6 | 574.86 | 500/1000 | |
8.37 | 11.57 | 0.641 | 0.796 | 183 | 4.6 | 27.9 | 6 | 701.07 | 500/1000 | |
9.95 | 13.55 | 0.443 | 0.550 | 228 | 6.4 | 32.7 | 6 | 878.21 | 500/1000 |
Aerial Bundle Conductor
Low-Voltage PVC Cable
Low Voltage Cable Description
Self Supporting system consists of four cores of drawn stranded and compacted aluminium conductors of equal cross-section and insulated with carbon-loaded XPLE to ensure to ensure UV protection. All cores strained equally.
Supporting-core system consists of three phase cores of hard-drawn stranded compacted aluminium conductors insulated with carbon-loaded XPLE laid up around an aluminium- alloy supporting core insulated with carbon loaded XPLE to ensure UV protection.
Additional sub-conductors optional in both self-supporting and supporting-core systems.
Head Office
240 Albert Amon Road
Meadowdale, Germiston
South Africa
Phone
(011) 453-8782/3
Fax
(011) 453-8789
Branch Office
Limpopo
Phone
(011) 453-8782/3